OH-Micro Focus ALM/QC-012616
Description
When user encounters OH-Micro Focus ALM/QC-012656, following error message will appear:
'Micro Focus ALM/QC-012616: Rest request processing Error : 500 Server Error : Probable cause for this error can be either the password entered in the System configuration form is wrong or the server has encountered the condition, which cannot process your request <request URL> (Please check the logs for the detailed response from server). OpsHub-012654: Error Occurred in HPQC CRUD Request execution for operation getMaxUpdateTime <Server Response Stack Trace> org.hp.qc.api.entities.InvalidValueForFieldException: Failed to convert the 'time' field of a 'audit-log'. The object 2000-01-01+00:00:00 cannot be converted to type QcDate
'
Cause
User will encounter this error in the following scenario:
When the user is running integration(s) of release-cycle in OpsHub Integration Manager having version 7.141 or above and your legacy Micro Focus application only accepts '%20' as the encoding of the ' ' (space character) in its API.
Solution
Open the directory where OpsHub Integration Manager is installed and navigate to
OpsHub_Resources/configdirectory.Duplicate the
HPQCProperty.properties.samplefile and rename it toHPQCProperty.properties.Now set the
hpQueryParamEncodingflag totrueand restart the OpsHub server service.